Pryco’s STANDARD Day Tanks are available in either a U/L Listed (Label #142) or a basic (non-U/L Listed) design. In addition to the standard features listed below, U/L Listed tanks have additional internal reinforcement, an emergency vent properly sized to the tank, and a U/L Listed label (File #MH12807 - Aboveground Tank for Flammable Liquids).

Standard features include:

  • Removable 61⁄2" Square Inspection Plate
    w/Gasket
  • Fuel Level Gauge
  • Heavy Duty Float Switch
  • Press-to-Test” Switch
  • Pump Running" Indicator Light
  • Four - 1" NPT Threaded Pipe Connections
  • One - 2" NPT Threaded Pipe Connection
    for Tank Vent
  • Tank Drain (Sized To Tank Capacity)
  • 1/3 hp thermally protected, 120vac, 1ph,
    60hz, motor
  • 2 gpm bronze gear pump w/stainless steel
    shafts
  • Lift Lugs (on tanks 50 gallons and over)
  • Removable top cover
  • Epoxy coating inside
  • Pryco (medium) Gray exterior paint (or an
    industrial color of choice)

 

Pryco-Day-Tank-Installed.jpg

Pryco Tanks are fabricated of heavy gauge steel by certified welders. Each tank complies with NFPA 30 and is tested to 5 psi. Shown to the right is a 25-gallon, U/L Listed, single-wall Standard Day Tank (PY25UL) with an optional #465 U/L Listed Enclosed Industrial Control Panel.

Double Wall Tanks

A totally enclosed outer shell may be added resulting in a double wall construction. Both the inner and the outer tanks are vented separately and are pressure tested at 5 psi.

When enclosing a U/L Listed day tank, an additional emergency vent is added to the outer tank the same size as the inner tank. (The U/L Listing is “Secondary Containment Aboveground Tank for Flammable Liquids”, File MH12807.)

Day Tanks with a capacity of 25 gallons and more have all threaded connections located on the tank top (except the overflow, drains, and the double wall vent). The inner tank drain is piped through the outer shell.

Rupture BasinPryco Day Tank installed inside containment dike

All Day Tanks can be set in a Rupture Basin (open top dike), including a tank with double wall construction. See Option 385 for sizes.

A Double Wall or a Rupture Basin may be equipped with an optional Leak Detector that will shut down the pump motor, turn on an alarm light and provide contacts for a remote signal — Options 295 and 395.

Weatherproof versions are also available.

Standard Day Tanks - Basic and U/L Listed - Single and Double Wall

  SINGLE WALL U/L LISTED SINGLE WALL R/B[1]
Size In US Gal. Model Weight Model Weight Vent Weight
5 PY5 88 PY5UL 92 2 67
10 PY10 94 PY10UL 98 2 82
15 PY15 109 PY15UL 113 2 87
25 PY25 122 PY25UL 126 2 102
50 PY50 192 PY50UL 166 2 165
60 PY60 185 PY60UL 192 3 180
75 PY75 200 PY75UL 207 3 215
100 PY100 220 PY100UL 227 3 247
150 PY150 266 PY150UL 273 3 311
200 PY200 385 PY200UL 396 4 434
275 PY275 453 PY275UL 464 4 515
300 PY300 463 PY300UL 469 4 530
400 PY400 532 PY400UL 543 4 588
500 PY500 573 PY500UL 584 4 732
600 PY600 613 PY600UL 624 4 787
700 PY700 660 PY700UL 671 4 854
800 PY800 703 PY800UL 714 4 935
900 PY900 747 PY900UL 771 6 998
1000 PY1000 789 PY1000UL 804 6 1082

 

DOUBLE WALL U/L LISTED DOUBLE WALL R/B[1]
Model Weight Model Weight Vent Weight
PY5DW 165 PY5ULDW 170 2 102
PY10DW 182 PY10ULDW 187 2 111
PY15DW 215 PY15ULDW 220 2 119
PY25DW 243 PY25ULDW 248 2 139
PY50DW 335 PY50ULDW 340 2 183
PY60DW 385 PY60ULDW 394 3 201
PY75DW 416 PY75ULDW 425 3 219
PY100DW 465 PY100ULDW 474 3 259
PY150DW 599 PY150ULDW 608 3 324
PY200DW 904 PY200ULDW 918 4 433
PY275DW 1104 PY275ULDW 1118 4 528
PY300DW 1117 PY300ULDW 1131 4 556
PY400DW 1279 PY400ULDW 1293 4 623
PY500DW 1391 PY500ULDW 1405 4 742
PY600DW 1484 PY600ULDW 1498 4 838
PY700DW 1619 PY700ULDW 1633 4 913
PY800DW 1810 PY800ULDW 1824 4 991
PY900DW 1925 PY900ULDW 1958 6 1071
PY1000DW 2003 PY1000ULDW 2036 6 1152